Juniper fpc 0 major errors. Clear the FPC errors on the device.

Juniper fpc 0 major errors. 2R1 and later. spares. Nov 20, 2023 · It is unhidden in Junos OS 18. Fabric errors triggered on a fabric plane. Jun 24, 2020 · jnxFruL3Index 0, jnxFruName Power Supply 1 @ 0/1/*, jnxFruType 7, jnxFruSlot 1, jnxFruOfflineReason 2, jnxFruLastPowerOff 0, jnxFruLastPowerOn 1978275966) Feb 8 15:07:34 alarmd[3571]: Alarm set: PS SFXPC color=YELLOW, class=CHASSIS, reason=FPC 0 PEM 1 is not powered May 21, 2020 · Solution An issue with Fabric connectivity from DPC. . It also provides details on how to overcome the alarm. e. 12: set chassis alarm fru-absence ignore fpc all pem 1 set chassis alarm fru-absence ignore fpc all pem 2 BEFORE: user@EX4100-12P> show system alarms 2 alarms currently active Alarm time Class Description 2024-06-06 12:00:00 UTC Major FPC 0 PEM 2 is not supported/powered 2024-06-06 12:00:00 UTC Major FPC Jan 22, 2025 · Since the FPC already wedged, the PFE would be disabled and a reboot of the FPC should fix the problem Modification History 2024-12-17 : Article Created Related Information Jul 16, 2024 · Please perform following to recover the FPC. Junos will make FPC offline when a trail of major errors is detected on the same FPC. Symptoms Active Alarm: user@host> show chassis alarms no-forwarding 4 alarms currently active Alarm time Class Description 2020-05-11 04:18:10 UTC Major FPC 3 misconfig 2020-05-11 04:18:10 UTC Major FPC 2 misconfig 2020-05-11 04:18:10 FPC0 will not come online for new cluster node. Check for the log messages to determine if there are any other logs that started this issue Dec 19, 2023 · Jul 27 13:22:21 craftd [13302]: Major alarm set, FPC 0 PEM 0 Feed A not connected. 585 craftd[11846]: Major alarm set, FPC 0 Major Errors - PE Error code: 0x210532 Jan 22, 2025 · Description FPC 0 Major errors on the device host and PFE 2 is showing as Fabric Disabled . Symptoms Logs: fpc0 PFE_ERROR_FAIL_OPERATION: Wedge op single step failed fpc0 Error: /fpc/0/pfe/0/cm/0/EA [2:0]-0/2/CMERROR_EACHIP_ERROR (0x40008), scope: board, category: functional, severity: major, module: EA [2:0]-0, type: LKUP_ASIC_DECLARE_WEDGE fpc0 PFE_ERROR_FAIL_OPERATION: Wedge op single step Jun 26, 2020 · Jun 9 22:01:11 alarmd[72819]: Alarm set: FPC color=RED, class=CHASSIS, reason=FPC 2 Major Errors - CPU Error code: 0x280003 Jun 9 22:01:11 fpc2 Cmerror: Draining ASIC error message queue Dec 20, 2023 · Description This article provides a comprehensive guide to troubleshoot the issue of MX204 chassis alarm “FPC 0 offlined due to excessive resets”. I confirmed working on Junos OS 22. "show chassis alarms" shows Major FPC 0 Hard errors. g. Symptoms MX router reports the following FPC Major Errors alarm, in the example below the alarm was reported by MPC5E card in slot 2: show system alarms user@device> show chassis alarms 1 Aug 6, 2024 · Description This article explains the meaning of the "FPC Major Error: PLL Error: XQ-0 PLL_LOCK:PWUP_CTRL_PLL_STATUS" alarm that is seen on MX Series routers and indicates if any actions need to be taken. , the number of times the error must occur before the action is triggered). Output fields are listed in the approximate order in which they appear. Check if there are active alarms on the device: Mar 2, 2023 · Much appreciated! When I was finally able to console in, I ran that command and see BUILTIN for FPC 0. 12: set chassis alarm fru-absence ignore fpc all pem 1 set chassis alarm fru-absence ignore fpc all pem 2 BEFORE: user@EX4100-12P> show system alarms 2 alarms currently active Alarm time Class Description 2024-06-06 12:00:00 UTC Major FPC 0 PEM 2 is not supported/powered 2024-06-06 12:00:00 UTC Major FPC Sep 17, 2024 · [LOG: Notice] Performing action get-state for error /fpc/4/pfe/0/cm/0/PIC1/0/PIC_CMERROR_TALUS_PKT_LOSS (0x31000d) in module: PIC1 with scope: board category: functional level: major Aug 6, 2024 · Description This article explains the meaning of the "FPC Major Error: PLL Error: XQ-0 PLL_LOCK:PWUP_CTRL_PLL_STATUS" alarm that is seen on MX Series routers and indicates if any actions need to be taken. > major FPC Major Level errors (default threshold = 1) > minor FPC Minor Level errors (default threshold = 10)user@host# set chassis fpc 0 error fatal action ? Apr 6, 2020 · In absence of that, I'd start by rebooting FPC 0. If you don't have spares, I'd power cycle the whole chassis (yes, can be a pain) and change slots (also a pain) before assuming the FPC is permanently faulty. The alarm triggers on the chassis when multiple major errors are reported on the FPC. If it doesn't normalize, your next best options are going to depend on what you have to work with, e. 4R3-S2. Jul 16, 2024 · Jun 14 23:20:52 <Hostename> : %PFE-5: fpc1 Performing action disable-pfe for error /fpc/1/pfe/0/cm/0/XMCHIP(0)/0/XMCHIP_CMERROR_PT_MEM_PROTECT_FSET_REG_DETECTED_CPT_FL_MEM (0x70295) in module: XMCHIP(0) with scope: pfe category: functional level: major May 13, 2020 · MQCHIP(0)-chan-rx-0 <= QXCHIP(0)-chan-tx-1 99520353703489 (13939454) 0 (0) MQCHIP(0)-chan-rx-2 <= LUCHIP(0)-chan-tx-2 758842696983198 (106278017) 0 (0) I have many errors related fpc Aug 5 16:01:05 re0-mx480-Inforelay chassisd [9368]: <FPC 0> ASIC Error detected errorno 0x00280002Aug 5 16:01:05 re0-mx480-Inf Jun 21, 2020 · 0 Major Errors long_reason=FPC 0 Major Errors - PE Error code: 0x210532 id=150995048 reason=150994944 Jun 20 10:41:20. You can classify the errors according to severity, set an automatic recovery action for each severity, and set a threshold (i. Modification History 2024-06-25 : Article Created vSRX Major FPC 0 Hard errors : r/Juniper r/Juniper Current search is within r/Juniper Remove r/Juniper filter and expand search to all of Reddit Output Fields Table 1 lists the output fields for the show chassis fpc errors command. The FPC then runs diagnostics, during which the OK LED blinks. Jul 27 13:22:21 Power Supply 0 added Jul 27 13:22:21 hwdb: entry for pem 0 at slot 0 inserted Jul 27 13:22:21 notify_fru_add: NULL kvpairs for Power Supply 0 Jul 27 13:22:21 pem_tvp_jdaf_info_update: psu_slot=0 input=1 expected=1 connected=0 Jun 30, 2024 · 2024-05-20 01:28:21 UTC Major FPC 0 Hard errors root@lab-router> show chassis fpc detail Slot 0 information: State Offline Reason Unresponsive Total CPU DRAM 0 MB Total HBM 0 MB FIPS Capable True Temperature 31 degrees C / 87 degrees F Max MPC base power consumption 0 Watts Max MPC total power consumption 0 Watts PFE Information: PFE Power ON Some Juniper devices include an internal framework for detecting and correcting FPC errors that can have the potential to affect services. Sep 16, 2024 · This article explains the major/minor alarms "FPC X Hard errors", "FPC X Temp Sensor Fail", and "FPC X Volt Sensor Fail" observed, their causes, and steps to mitigate the issues. request chassis fpc slot 1 restart Restarting the FPC should clear the alarm, if the restart does not help clear the alarm, - Reseat the FPC in MW, if the issue is still seen, reach out to JTAC for further troubleshooting. The Routing Engine downloads the FPC software to it under two conditions: the FPC is present when the Routing Engine boots Junos OS, and the FPC is installed and requested online through the CLI or push button on the front panel. It is important to identify the trigger of major errors to investigate Clear the FPC errors on the device. Jul 9, 2024 · The device will have alarms "Major FPC 0 Fan I2C Failure" and will log these alarm in log messages continuously Solution Kindly check below details , Check "show chassis hardware and "show chassis environment " to check if Fan is detected and working fine. Hardware issue with FPC. Traffic or permanent packet forwarding on the Packet Forwarding Engine (PFE) may be impacted if the errors are seen repeatedly and may require replacement of the FPC. Unreachable destinations from FPC. Symptoms MX router reports the following FPC Major Errors alarm, in the example below the alarm was reported by MPC5E card in slot 2: show system alarms user@device> show chassis alarms 1 May 27, 2021 · user@device> show chassis alarms 1 alarm currently active Alarm time Class Description 2020-12-29 23:18:38 GMT Major FPC 0 Major Errors Jun 16, 2020 · Description This article explains the meaning of the 'FPC x misconfig' major alarm on SRX series devices. user@mx> clear chassis fpc errors fpc-slot fpc-slot (all | error-id error-id) Note: It is suggested to use all instead of a particular error-id to work around the complicated error-id format, which is represented as a Uniform Resource Identifier (URI). Use this command to have the PSU alarm ignored. "show chassis fpc 0 detail" reveals fpc 0 is offline and unresponsive. Jun 19, 2020 · If the issue is seen repeatedly even after restarting the FPC, open a Technical Service Request for further investigation and assistance. You can choose to clear a particular error or all errors on the FPC. Fabric drops. Nov 8, 2024 · Aug 20 08:40:23 MX craftd [16303]: Major alarm set, FPC 5 Major Errors - XM Chip Error code: 0x70067 A single occurrence of the above syslog events occurs, then it indicates a one-time hardware error. Feb 9, 2021 · 2021-01-31 02:37:43 PST Major FPC 0 Major Errors - PE Error code: 0x210001 This article explains why the above alarm may persist after auto-correction of the HMC error and indicates that rebooting the line card will resolve the problem. Reboot the FPC 1 in an MW. jxt 4v3 t4h neejw2u wwet n8d2 yvhr5 gjtjc vvliqwy d65